Menu
Back
  1. Products
  2. Automation technology - Data transmission
  3. M8-D
  4. M8 Male angled panel mount connector, Contacts: 4, shieldable, THT, IP67
Part no.: 86 6321 1121 00404

M8 Male angled panel mount connector, Contacts: 4, shieldable, THT, IP67

M8-D, series 818, Automation Technology - Data Transmission
Compare product
Downloads
This male panel mount connector, gewinkelt with screw locking and a pin count of 4 is according to its protection class IP67 Dust-tight and has complete protection against contact and protection against temporary immersion. It can be used in areas with a pollution degree of 3. In places where contamination can occur that is conductive or can become conductive through condensation. With temperatures ranges of -40 °C/85 °C is this shieldable M8-D coded male panel mount connector, gewinkelt designed for both severe cold and severe heat. Due to the qualified rated voltage of 63 V DC and the rated current of 4,0 A it is perfectly tuned for its field of application. It complies with the type standard DIN EN 61076-2-114.
General features
Moreless
Part no. 86 6321 1121 00404
Connector design Male angled panel mount connector
Type standard DIN EN 61076-2-114
Version Connector pin angled
Connector locking system screw
Termination THT
Degree of protection IP67
Temperature range from/to -40 °C / 85 °C
Mechanical operation > 100 Mating cycles
Weight (g) 4.84
Customs tariff number 85369010
Country of Origin DE
Rated voltage 63 V DC
Rated impulse voltage 1500 V
Rated current 4.0 A
Insulation resistance > 108 Ω
Pollution degree 3
Insulating material group III
EMC compliance shieldable
Shield connection Shielding plate
Housing material Zinc die-cast nickel-plated
Contact body material PA yellow/green
Contact material CuZn (brass) / CuSn (bronze)
Contact plating Au (gold)
REACH SVHC CAS 7439-92-1 (Lead)
SCIP number d1070752-a819-432e-a5e2-f9e86b2ad9f5
eCl@ss 11.1 27-44-01-09
ETIM 9.0 EC003569
General Disclaim Notice
  1. The connector must not be plugged or unplugged under load. Non-observance and improper use can result in personal injury.
  2. The connectors have been developed for applications in plant engineering, control and electrical equipment construction. The user is responsible for checking whether the connectors can also be used in other areas of application.
  3. Connectors which are used in circuits with voltages dangerous to the touch may only be installed and used by, or under the supervision of, persons with electrical engineering training, taking into account the applicable regulations and standards.
  4. The user must take suitable safety precautions to ensure that the connector cannot be accidentally disconnected.
  5. Plug connectors with enclosure protection IP67 and IP68 are not suitable for use under water. When used outdoors, the plug connectors must be protected separately against corrosion. For further information on the IP protection classes, please refer to the "Technical Information" download centre.
  6. The plug connector is not suitable for mains voltages Please observe the pollution degree and the overvoltage category. For further information, please refer to the download center "Technical Information".
  7. To lock the cable connector with the device connector, the threaded ring is tightened "hand-tight" (approx. 40 cNm).
Downloads
Data sheet
Data sheet 86 6321 1121 00404
PDF
REACH
86 6321 1121 00404
PDF
RoHS
86 6321 1121 00404
PDF
China RoHS
86 6321 1121 00404
PDF
CAD files
Select required format
M8-D
86 6321 1121 00404